Request a Quote

Get Started

4040 StingRay Parts Washer

Retractable Turntable Industrial Parts Washer

Stingray Industrial Parts Washer SR4040

The StingRay 4040 Aqueous Parts Washer is engineered for cleaning over-road truck transmission and carrier rebuilders. The versatile design of the StingRay 4040 provides excellent cleaning power and short wash cycles for heavy duty soils. This industrial parts washer is very popular for cleaning and degreasing engines and transmissions in truck component and off-road rebuilders like Caterpillar and Komatsu, as well as many rail shops for brake and power pack rebuilding. It is also available with an extended 63" work height for washing taller parts.

USA Specifications:

SR 4040 Parts Washer

Metric Specifications:

SR 4040 Parts Washer

Standard Features & General Construction:

  • Green Technology: Closed Loop Zero Discharge
  • Heavy 7 gauge (3/16 inch) thick cabinet walls and reservoir
  • Swing Door Retracting Turntable for Maximum Access
  • Electronic Water Level Control & Refill
  • Oscillating Wash Manifold to Maximize Cleaning
  • Easy to Service Front Wash Pump Suction Strainer
  • Adjustable Electronic Temp Control, Temp Gauge
  • Control Transformer External of Panel minimizes Heat
  • Programmable 24 Hour 7 Day Clock
  • Low Water Shut-off Protects Pumps & Heating System
  • Electronic Door Safety Interlock
  • Wash Cycle Timer with Auto Reset
  • Heavy gauge 3/16" Sheet Steel Cabinet Thickness
  • 208V, 230 V or 460 V - 60 Hz 3-Phase with 120 V Controls
  • 50 Hertz 380V and other worldwide voltages available
  • Chemical Resistant Two Part 3 mil Epoxy Coating

 

Work Area Dimensions:
Turntable Diameter:
US41 inches
Metric1040 mm
Work Height:
US39 inches
Metric990 mm

Table Load Capacity:

US1500 lbs
Metric680 kg
Heavy Duty Capacity:
US3500 lbs
Metric1590 kg
Work Area Dimensions: US Metric
Turntable Diameter: 41 inches 1040 mm
Work Height: 39 inches 990 mm

Table Load Capacity:

1500 lbs 680 kg
Heavy Duty Capacity: 3500 lbs 1590 kg
Overall Dimensions:
Width: (Std Unit)
US79 inches
Metric2000 mm
Depth: (Std Unit)
US74 inches
Metric1870 mm
Height:
US83 inches
Metric2100 mm
Empty Weight:
US3900 lbs
Metric1770 kg
Reservoir Capacity:
US180 gallons
Metric681 liters
Duplex Reservoir:
USAdd 47 gallons
MetricAdd 178 liters
Sludge Capacity:
US47 gallons
Metric178 liters
Overall Dimensions: US Metric
Width: (Std Unit) 79 inches 2000 mm
Depth: (Std Unit) 74 inches 1870 mm
Height: 83 inches 2100 mm
Empty Weight: 3900 lbs 1770 kg
Reservoir Capacity: 180 gallons 681 liters
Duplex Reservoir: Add 47 gallons Add 178 liters
Sludge Capacity: 47 gallons 178 liters
Spray Blast Manifold:
OSCILLATING NON-SYNCHRONOUS
Angle of Oscillation: (Picture)
39 Degrees
Frequency of Oscillation:
4 per minute
Number of Wash Nozzles: (Picture)
16
Type of Nozzle:
V-Jet
Nozzle Material:
316 Stainless
Spray Blast Manifold:
OSCILLATING NON-SYNCHRONOUS
Angle of Oscillation: (Picture) 39 Degrees
Frequency of Oscillation: 4 per minute
Number of Wash Nozzles: (Picture) 16
Type of Nozzle: V-Jet
Nozzle Material: 316 Stainless
Heating System:
Operating Temperature:
US140-190 degrees F
Metric60-88 degrees C
Initial Heat up Time:
US60-90 minutes
Metric60-90 minutes
Electric Heat Element Size: (Picture)**
US30 kW
Metric30 kw
 Gas / Propane (Picture)
US 180,000 BTU/hr
Metric 53 kW
Heating System: US Metric
Operating Temperature: 140-190 degrees F 60-88 degrees C
Initial Heat up Time: 60-90 minutes 60-90 minutes
Electric Heat Element Size: (Picture)** 30 kW 30 kw
 Gas / Propane (Picture)  180,000 BTU/hr  53 kW
Electrical Panel (Picture)
Motor Starters:
USAcross the Line
MetricIEC Type 2
Short Circuit Protection:
USStd
MetricCoordinated
Overload Protection:
USStd
MetricThermal Class 10
Electrical Enclosures:
USNEMA 12
MetricIP65
Wiring Standard:
USNFPA 79
Metric NFPA 79
Wiring Conduit:
USFlex-Non-Metallic
MetricFlex-Non-Metallic
Conduit Type:
USLiquidtight Nema 12
MetricLiquidtight IP65
Electrical Panel (Picture) US Metric
Motor Starters: Across the Line IEC Type 2
Short Circuit Protection: Std Coordinated
Overload Protection: Std Thermal Class 10
Electrical Enclosures: NEMA 12 IP65
Wiring Standard: NFPA 79  NFPA 79
Wiring Conduit: Flex-Non-Metallic Flex-Non-Metallic
Conduit Type: Liquidtight Nema 12 Liquidtight IP65
Pump System & Performance:
Motor Type: (Picture)
 Energy-Efficient NEMA MG-1
Motor Rating:
 Continuous Duty
Motor Enclosures:
 TEFC
Pump System & Performance:  
Motor Type: (Picture) Energy-Efficient NEMA MG-1
Motor Rating: Continuous Duty
Motor Enclosures: TEFC

High Efficiency, Rated for continuous duty (20 Start/hour without overheating), vertical, centrifugal, seal-less, balanced, enclosed impeller. Note: All performance data taken at nozzle discharge.

STANDARD:
Total System Flow:
10 hp (US)180 gpm
7.5 kW (Metric)681 l/min
Flow per Nozzle:
10 hp (US)11.3 gpm
7.5 kW (Metric)43 l/min
System Pressure:
10 hp (US)75 psi
7.5 kW (Metric)5.2 bar
Blast Velocity:
10 hp (US)105 ft/sec
7.5 kW (Metric)32 m/sec
Power Density:
10 hp (US)0.34 hp/ft³
7.5 kW (Metric)8 kW/m³
STANDARD: 10 hp (US) 7.5 kW (Metric)
Total System Flow: 180 gpm 681 l/min
Flow per Nozzle: 11.3 gpm 43 l/min
System Pressure: 75 psi 5.2 bar
Blast Velocity: 105 ft/sec 32 m/sec
Power Density: 0.34 hp/ft³ 8 kW/m³

 

UPGRADES: (SIMPLEX)
Total System Flow:
20 hp (US)221 gpm
15 kW (Metric)835 l/min
30 hp (US)256 gpm
22 kW (Metric)979 l/min
40 hp (US)268 gpm
30 kW (Metric)1010 l/min
Flow per Nozzle:
20 hp (US)13.8 gpm
15 kW (Metric)52 l/min
30 hp (US)16.0 gpm
22 kW (Metric)61 l/min
40 hp (US)16.8 gpm
30 kW (Metric)64 l/min
System Pressure:
20 hp (US)112 psi
15 kW (Metric)7.7 bar
30 hp (US)152 psi
22 kW (Metric)10.5 bar
40 hp (US)165 psi
30 kW (Metric)11.4 bar
Blast Velocity:
20 hp (US)129 ft/sec
15 kW (Metric)39 m/sec
30 hp (US)150 ft/sec
22 kW (Metric)46 m/sec
40 hp (US)156 ft/sec
30 kW (Metric)48 m/sec
Power Density:
20 hp (US).71 hp/ft³
15 kW (Metric)17 kW/m³
30 hp (US)1.06 hp/ft³
22 kW (Metric)25 kW/m³
40 hp (US)1.41 hp/ft³
30 kW (Metric)33 kW/m³
UPGRADES: (SIMPLEX) 20 hp (US) 15 kW (Metric) 30 hp (US) 22 kW (Metric) 40 hp (US) 30 kW (Metric)
Total System Flow: 221 gpm 835 l/min 256 gpm 979 l/min 268 gpm 1010 l/min
Flow per Nozzle: 13.8 gpm 52 l/min 16.0 gpm 61 l/min 16.8 gpm 64 l/min
System Pressure: 112 psi 7.7 bar 152 psi 10.5 bar 165 psi 11.4 bar
Blast Velocity: 129 ft/sec 39 m/sec 150 ft/sec 46 m/sec 156 ft/sec 48 m/sec
Power Density: .71 hp/ft³ 17 kW/m³ 1.06 hp/ft³ 25 kW/m³ 1.41 hp/ft³ 33 kW/m³

 

 UPGRADES: (DUPLEX)
Total System Flow:
55 hp (US)303 gpm
41 kW (Metric)1150 l/min
Flow per Nozzle:
55 hp (US)18.9 gpm
41 kW (Metric)72 l/min
System Pressure:
55 hp (US)212 psi
41 kW (Metric)14.6 bar
Blast Velocity:
55 hp (US)177 ft/sec
41 kW (Metric)54 m/sec
Power Density:
55 hp (US)1.94 hp/ft³
41 kW (Metric)46 kW/m³
 UPGRADES: (DUPLEX) 55 hp (US) 41 kW (Metric)
Total System Flow: 303 gpm 1150 l/min
Flow per Nozzle: 18.9 gpm 72 l/min
System Pressure: 212 psi 14.6 bar
Blast Velocity: 177 ft/sec 54 m/sec
Power Density: 1.94 hp/ft³ 46 kW/m³

 

Results may vary based on machine configuration.
** Heating element sizes listed for 208, 240 & 480 volt systems. Sizes vary slightly for other voltages.

 

StingRay Parts Washers

HD Retractable Turntable Models
In-line Lift Door
Aircraft Wheel Washer Systems