Dual Lift Door Inline Parts Washers StingRayThe StingRay 6048 Inline Dual Lift Door Parts Washer not only offers an impressive parts washer power density for parts cleaning but also the patented oscillating power wash manifold to maximize parts cleaning in any industrial application. The parts washer is designed for conveyor feed for maximum throughput in automated parts cleaning process lines such as in the cleaning of rail bearings for reconditioning and rebuild.

The parts washer is designed to automatically clean a standardized pallet load of parts. Dual entrance and exit lift doors automatically open for loading and unloading of parts.  Turntable roller tracks are designed to receive a standardized pallet with a basket or a fixture load of parts, the track rollers mate with feed and discharge rollers located outside the cabinet. The machine locks the standard pallet loaded with parts onto the turntable for cleaning.

StingRay offers various levels of automation depending on the needs of the end user. Powered entrance and exit conveyors are available for feed and discharge of the wash load.  An automatic loading device that moves pallets from the entrance conveyor onto the turntable is available as an option. Full automation is available whereby pallet loads queued at the entrance conveyor are automatically processed through the escapement mechanism, cleaned and discharged without operator intervention.

USA Specifications:

SR 6048 Parts Washer

Metric Specifications:

SR 6048 Parts Washer

Standard Features & General Construction

In-Line Lift Door Parts Washer

  • Green Technology: Closed Loop Zero Discharge
  • Dual Lift Door System to Maximize Loads per Shift
  • Electronic Water Level Control & Refill
  • Oscillating Wash Manifold to Maximize Cleaning
  • Easy to Service Front Wash Pump Suction Strainer
  • Adjustable Electronic Temp Control, Temp Gauge
  • Control Transformer External of Panel minimizes Heat
  • Programmable 24 Hour 7 Day Clock
  • Low Water Shut-off Protects Pumps & Heating System
  • Electronic Door Safety Interlock
  • Wash Cycle Timer with Auto Reset
  • Heavy gauge 3/16" Sheet Steel Cabinet Thickness
  • 230 V or 460 V - 60 Hz 3-Phase with 120 V Controls
  • Chemical Resistant Two Part 3 mil Epoxy Coating
Work Area Dimensions: US Metric
Turntable Diameter: 60 inches 1520 mm
Work Height: 48 inches 1210 mm

Table Load Capacity:

2000 lbs 907 kg
Heavy Duty Capacity: 3500 lbs 1588 kg
Overall Dimensions: US Metric
Width: (Std Unit) 104 inches 2640 mm
Depth: (Std Unit) 82 inches 2080 mm
Height: 172 inches 4370 mm
Empty Weight: 6650 lbs 3012 kg
Reservoir Capacity: 350 gallons 1325 liters
Duplex Reservoir: Add 47 gallons 178 liters
Sludge Capacity: 80 gallons 303 liters
Spray Blast Manifold:
OSCILLATING NON-SYNCHRONOUS Video
Angle of Oscillation: (Picture) 39 Degrees
Frequency of Oscillation: 4 per minute
Number of Wash Nozzles: (Picture) 20
Type of Nozzle: V-Jet
Nozzle Material: 316 Stainless
Heating System: US Metric
Operating Temperature: 140-190 degrees F 60-87 degrees C
Initial Heat up Time: 60-90 minutes 60-90 minutes
Electric Heat Element Size: (Picture)** 80 kW 80 kw
 Gas / Propane (Picture)  550,000 BTU/hr  161 kW
Electrical Panel (Picture) US Metric
Motor Starters: Across the Line Across the Line
Short Circuit Protection: Std Std
Overload Protection: Std Std
Electrical Enclosures: NEMA 12 IP65
Wiring Standard: NFPA 79  
Wiring Conduit: Flex-Non-Metallic Flex-Non-Metallic
Conduit Type: Liquidtight Nema 12 Liquidtight IP65
Pump System & Performance:  
Motor Type: (Picture) Energy-Efficient
Motor Rating: Continuous Duty
Motor Enclosures: TEFC

High Efficiency, Rated for continuous duty (20 Start/hour without overheating), vertical, centrifugal, seal-less, balanced, enclosed impeller. Note: All performance data taken at nozzle discharge.

STANDARD: 20 hp (US) 15 kW (Metric)
Total System Flow: 269 gpm 1017 l/min
Flow per Nozzle: 13.5 gpm 51 l/min
System Pressure: 107 psi 7 bar
Blast Velocity: 126 ft/sec 38 m/sec
Power Density: 0.25 hp/ft³ 6 kW/m³

 

UPGRADES: (SIMPLEX) 30 hp (US) 22 kW (Metric) 40 hp (US) 30 kW (Metric)
Total System Flow: 301 gpm 1138 l/min 319 gpm 1206 l/min
Flow per Nozzle: 15.1 gpm 57 l/min 16.0 gpm 61 l/min
System Pressure: 134 psi 9 bar 150 psi 10 bar
Blast Velocity: 141 ft/sec 43 m/sec 149 ft/sec 45 m/sec
Power Density: 0.38 hp/ft³ 9 kW/m³ 0.51 hp/ft³ 12 kW/m³

 

UPGRADES: (DUPLEX) 55 hp (US) 41 kW (Metric) 70 hp (US) 52 kW (Metric)
Total System Flow: 356 gpm 1346 l/min 371 gpm 1402 l/min
Flow per Nozzle: 17.8 gpm 67 l/min 18.6 gpm 70 l/min
System Pressure: 187 psi 13 bar 203 psi 14 bar
Blast Velocity: 166 ft/sec 51 m/sec 173 ft/sec 53 m/sec
Power Density: 0.7 hp/ft³ 17 kW/m³ 0.89 hp/ft³ 21 kW/m³

 

Results may vary based on machine configuration.
** Heating element sizes listed for 208, 240 & 480 volt systems. Sizes vary slightly for other voltages.

 

StingRay Parts Washers

HD Retractable Turntable Models
In-line Lift Door
Aircraft Wheel Washer Systems